LCD50+5X440R HVAC ROUND DUAL RUN CAPACITOR
Engineered by an ISO manufacturer with over twenty years' experience in OEM capacitor fabrication, Linebacker® capacitors are manufactured by the OEM factory and are 100% in-line production tested to the same rigorous standards.
Features/Benefits
10,000 AFC pressure sensitive short circuit interrupting capability
3-year warranty from the date of purchase
Continuous life tested, oil leak tested and dielectric tested for insulation effectiveness
Life tested to 85° C operating temperature for 10,000 cycles
Manufactured with thick polypropylene foil to handle increased operating temperatures
Meets EIA-456A accelerated life test at 70° C for 60,000 hours
PCB-free oil to prevent over-heating
UL File # E352486
US and Canada UL approved (C22.2NO.190)
Specification:
Voltage:
Up to 440 VAC
Operating Temperature:
-40°F to 185°F (-40°C to 85°C)
Foil Thickness:
6.0 µm +/- 5%
Standard Tolerance:
+/- 5%
MFD Value:
50+5
Style:
Round
Size:
1.97x4.33
California Residents only
WARNING: Cancer and/or Reproductive Harm - www.p65warnings.ca.gov
Supco DP402402 HVAC&R 2 Pole Definite Purpose Contactor
Supco® contractors are designed for use in HVACR systems. These contactors are available in 1.5, 2 and 3 pole configurations from 20 through 90 full amps. Compact universal design allows replacement of the most common brands.
Features
CSA approved
Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
UL® Recognized
Specification:
Operating Temperature:
-40°F to 150°F (-40°C to 65°C)
Termination Torque:
35-inch pounds
Termination:
Box Lug
Resistive Load Amperage (RLA):
50A
Number of poles:
2 Pole
Coil voltage:
240V
Full load amps:
40 FLA
California Residents only
WARNING: Cancer and/or Reproductive Harm - www.p65warnings.ca.gov
Supco DP601203 HVAC&R 3 Pole Contactor 120V, 60FLA, 75RLA
Features
CSA approved
Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
UL® Recognized
Specification:
Termination Torque:
35-inch pounds
Operating Temperature:
-40°F to 150°F (-40°C to 65°C)
Termination:
Box Lug
Resistive Load Amperage (RLA):
75A
Number of poles:
3 Pole
Coil voltage:
120V
Full load amps:
60 FLA
California Residents only
WARNING: Cancer and/or Reproductive Harm - www.p65warnings.ca.gov
Supco SXT116 HVAC Foot Mount Transformer 40VA, 120V - 24V
A complete line of control transformers designed for HVAC/R applications. Primary Voltage: 120V. Secondary Voltage: 24V.
Features
Class 2 Rated
Foot-Mount
Output VA: 40VA
Primary: 120VAC
Secondary: 24VAC
Replacement Part: Honeywell AT40A1121, AT40B1206, White-Rodgers 90-T40F1, Mars 50352, Jard 4011F
This is an aftermarket part that can be used as a replacement for the OEM part.
California Residents only