WP3392519 Genuine OEM Whirlpool Dryer Thermal Fuse
The WP3392519 is a genuine Whirlpool OEM thermal fuse mounted on the blower housing next to the blower fan. This fuse is a one-time safety device: as long as the dryer stays within its normal operating temperature, it does nothing at all, but the instant internal temperatures climb high enough — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power to the dryer. That's why a blown thermal fuse produces such a specific symptom: the dryer won't start at all, with no lights, no tumble, and no response, even though the outlet has power.
This fuse opens at approximately 196°F (91°C) and terminates in two 3/16" wire terminals for a direct plug-in fit. Unlike a resettable thermostat, this thermal fuse cannot be reset once it blows — it must be replaced. A blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat is exactly what the fuse is designed to react to. A shorted heating element or a failed regulating thermostat can also cause the dryer to run hot enough to blow the fuse. It directly replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, and 80005.
Quick Answer
The WP3392519 Genuine OEM Whirlpool Dryer Thermal Fuse fixes Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, and Amana dryers that won't start at all — no lights, no tumble, no response to any button. Opens at approximately 196°F (91°C). Two 3/16" wire terminals. Replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, 80005. Always inspect and clean the dryer venting when replacing this fuse — a blown fuse is a symptom of restricted airflow, and installing a new fuse without fixing the vent will likely blow it again.
Common Problems This Part Fixes
Dryer won't start at all — no lights, no tumble, no response to any button
Dryer that stopped working suddenly, especially after running unusually hot
Dryer runs a short time then shuts off completely and won't restart
Repeated blown fuses on a dryer with a known venting or airflow restriction
Clothes coming out extremely hot right before the dryer stopped working
Dryer that recently smelled like burning or overheating before failing
Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermal fuse directly replaces the following OEM and cross-reference part numbers:
3392519, WP3392519, 3388651, WE4X857, G4AP0500, 6L4101, 6L4101091C, ET401, 3388651, 694511, 80005, AWP47582, PD00002311, EAP11741460, AP6008325, PS11741460
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal fuse is compatible with select Whirlpool-built dryers across the Whirlpool family of brands, including:
Whirlpool electric and gas dryers — WED, WGD series
Maytag electric and gas dryers — MEDC, MGDC series (select Whirlpool-built models)
Kenmore dryers (select Whirlpool-built models)
KitchenAid, Jenn-Air, and Amana dryers (select models)
Roper, Estate, Inglis, and Crosley dryers (select models)
Verified model numbers include: MEDC465HW0, MGDC465HW0, WED4850HW0, WED4950HW0, WED49STBW1, WET4024HW0, WET4124HW0, WGD4850HW0, WGD4950HW0, YMEDC465HW0, YWED4850HW0, and YWET4024HW0.
Note: This fuse also fits select commercial and stacked washer/dryer combination units on the Whirlpool platform. Always verify your full model number before ordering. Contact our support team with your model number if you're unsure.
Key Features
Genuine Whirlpool OEM part — factory-specified opening temperature and terminal configuration
One-time safety device that cuts power if the dryer overheats
Opens at approximately 196°F (91°C)
Resolves "won't start at all," "stopped working suddenly," and "clothes came out extremely hot before it died" symptoms caused by a blown fuse
Two 3/16" wire terminal connectors for a direct plug-in electrical fit
Mounts to the blower housing next to the blower fan
Replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, and 80005
Compatible with Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, and Amana dryers
Genuine OEM replacement — guaranteed fit, materials, and performance
Product Specifications
Part Number
WP3392519
Part Type
Dryer Thermal Fuse (Thermal Cut-Off)
Condition
Genuine OEM
Brand
Whirlpool
Opening Temperature
Approx. 196°F (91°C)
Location
Blower housing, next to the blower fan
Terminals
2 (3/16" wire terminals)
Resettable
No — one-time use, must be replaced once blown
Dimensions
Approx. 2" x 1/2"
Repair Difficulty
Medium — basic disassembly required
Quantity
1 thermal fuse
Compatible Brands
Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, Amana, Estate, Inglis, Crosley
Installation Notes
⚠️ Unplug Dryer Before Starting — Inspect And Clean The Venting Before Reassembling Disconnect power at the outlet or shut off the circuit breaker before beginning. Wear work gloves. Access is typically through the rear panel: remove the screws securing the panel to reach the blower housing where the fuse is mounted. Photograph the wiring before disconnecting the wire terminals from the old fuse. Remove the mounting screw holding the fuse in place and pull it free, disconnecting both wire terminals. Before installing the new fuse, test it for continuity with a multimeter to confirm it's good out of the box, and test the old one to confirm it's actually blown (no continuity) rather than assuming. This is the most important step: fully inspect and clean the dryer's exhaust vent, from the lint trap housing all the way to the exterior vent hood, checking for lint buildup, crushed sections, or excessive length. A blown thermal fuse is a symptom of restricted airflow, and skipping this step means the new fuse is likely to blow again. Install the new WP3392519 in the same mounting position, reconnect both wire terminals, and secure the mounting screw. Reinstall the rear panel, restore power, and run a test cycle to confirm normal heating and shutoff behavior. Tools needed: Phillips or nut driver (model-dependent), multimeter, vent brush or vacuum attachment for cleaning ductwork, work gloves.
Frequently Asked Questions
My dryer has no power at all and the lights won't turn on. Is this the thermal fuse?
It's a strong possibility. When this thermal fuse blows, it cuts power broadly enough that the console lights and control panel can go completely dark, not just the heating function — that's a normal result of how this fuse is wired into the circuit. Before replacing it, confirm the outlet has power and the breaker hasn't tripped, then check the fuse for continuity with a multimeter. If it shows no continuity, this fuse is the correct fix, though it's also worth checking the exhaust ducting since that's the most common underlying cause.
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. If airflow checks out and the fuse still blows, have the heating element and cycling thermostat checked as well, since a component stuck in the "on" position can also drive excess heat.
Can I just reset the thermal fuse instead of replacing it?
No. Unlike a cycling thermostat, this thermal fuse is a one-time safety device — once it blows, its internal circuit is permanently broken and it cannot be reset or repaired. Replacement is the only option.
My clothes came out extremely hot right before the dryer died. Is that related?
Yes, this is a classic warning sign. Clothes coming out unusually hot indicates the dryer was already running hotter than normal, which is exactly the condition that leads to a blown thermal fuse. If you noticed this before the dryer stopped working, it strongly points to a ventilation or airflow problem that should be fully addressed before running the dryer again.
Is this an OEM or aftermarket part?
This is a genuine OEM part, manufactured by Whirlpool to factory specifications — guaranteed fit, materials, and performance. It matches the original opening temperature, terminal configuration, and mounting position of the thermal fuse originally installed in your dryer.
Shop With Confidence
A U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock components for all major appliance brands and offer fast shipping from our U.S. warehouse. Our team is available to help verify compatibility before you purchase.
✓ Genuine OEM Parts ✓ Fast US Shipping ✓ Compatibility Support ✓ Secure Checkout
XPARTCO DC96-00887C Dryer Thermal Cut Off Fuse
The XPARTCO DC96-00887C is an aftermarket replacement thermal cut-off fuse for Samsung and select Kenmore electric dryers, mounted with its bracket on the blower housing. This fuse is a one-time safety device: as long as temperatures around the blower stay within normal range, it does nothing at all, but the instant they climb high enough — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power to protect the dryer. That's why a blown fuse at this location produces such a specific symptom: the dryer won't start at all, with no lights, no tumble, and no response, even though the outlet has power.
Despite frequently being labeled a "thermostat" on third-party marketplaces, this is genuinely a fuse, not a thermostat — once it opens from excess heat, it stays open permanently and cannot reset itself. It ships complete with its mounting bracket for a direct plug-in fit. A blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat is exactly what this fuse is designed to react to. It directly replaces DC96-00887A, AP5966894, 2074129, AP4207819, PS4216838, EAP4216838, WP35001193, 35001193, PS11741822, PS11741829, and AP6008689.
Quick Answer
The XPARTCO DC96-00887C Dryer Thermal Cut Off Fuse fixes Samsung and select Kenmore electric dryers that won't start at all — no lights, no tumble, no response to any button. Mounted with bracket on the blower housing. Replaces DC96-00887A, AP5966894, 2074129, AP4207819, PS4216838, EAP4216838, WP35001193, 35001193, PS11741822, PS11741829, AP6008689. This is a different fuse from our DC47-00016A listing, which mounts on the heater can rather than the blower housing — always verify which fuse your dryer's parts diagram calls for.
Common Problems This Part Fixes
Dryer won't start at all — no lights, no tumble, no response to any button
Dryer that stopped working suddenly, especially after running unusually hot
Dryer runs a short time then shuts off completely and won't restart
Repeated blown fuses on a dryer with a known venting or airflow restriction
Clothes coming out extremely hot right before the dryer stopped working
Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermal cut-off fuse directly replaces the following OEM and cross-reference part numbers:
DC96-00887C, DC96-00887A, PD00035400, EAP4216838, AP5966894, ASM65115, PD00035400, PS4276292, WP35001193, 35001193, PD00003365, EAP11741829, AP6008689, AWP47381, PD00003365, PS11741829.
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal cut-off fuse is compatible with select Samsung electric dryers, and also fits select Kenmore dryers built on the Samsung platform, including model numbers such as:
DV5471AEW/XAA
DV40J3000EW/A2, DV42H5000EW/A3, DV45H7000EW/A2, DV48H7400EW/A2
DV400EWHDWR/AA
DVE50M7450W/A3
Note — not the same as DC47-00016A: This fuse mounts on the blower housing. Our DC47-00016A listing is a separate thermal fuse that mounts on the heater can instead — the two guard different points in the same circuit and are not interchangeable. Always verify your full model number and check your parts diagram for the exact mounting location before ordering. Contact our support team with your model number if you're unsure which fuse your dryer needs.
Key Features
Aftermarket replacement thermal cut-off fuse — one-time safety device that cuts power if the dryer overheats
Mounted with its bracket on the blower housing for a direct plug-in fit
Resolves "won't start at all," "stopped working suddenly," and "clothes came out extremely hot before it died" symptoms caused by a blown fuse
Genuinely a fuse, not a thermostat, despite common marketplace mislabeling — non-resettable once blown
Replaces DC96-00887A, AP5966894, 2074129, AP4207819, PS4216838, EAP4216838, WP35001193, 35001193, PS11741822, PS11741829, and AP6008689
Compatible with Samsung and select Kenmore electric dryers
Aftermarket replacement built to OEM-equivalent quality standards
Product Specifications
Part Number
DC96-00887C
OEM Part Number
DC96-00887C
Part Type
Dryer Thermal Cut-Off Fuse (with Bracket)
Condition
Aftermarket Replacement
Location
Blower housing
Resettable
No — one-time use, must be replaced once blown
Related Component
DC47-00018A high-limit thermostat (different device, same circuit, sold separately)
Quantity
1 thermal fuse with bracket
Compatible Brands
Samsung, select Kenmore
Installation Notes
⚠️ Unplug Dryer Before Starting — Inspect And Clean The Venting Before Reassembling Disconnect power at the outlet or shut off the circuit breaker before beginning. Wear work gloves. Access is typically through the rear panel: remove the screws securing the panel to reach the blower housing where the fuse is mounted. Photograph the wiring before disconnecting the old fuse's connectors. Remove the mounting screw holding the fuse and bracket in place, and pull it free, disconnecting both wire terminals. Before installing the new fuse, test it for continuity with a multimeter to confirm it's good out of the box, and test the old one to confirm it's actually blown (no continuity) rather than assuming. This is the most important step: fully inspect and clean the dryer's exhaust vent, from the lint trap housing all the way to the exterior vent hood, checking for lint buildup, crushed sections, or excessive length. A blown thermal fuse is a symptom of restricted airflow, and skipping this step means the new fuse is likely to blow again. Install the new DC96-00887C in the same mounting position, reconnect both wire terminals, and secure the mounting screw. Reinstall the rear panel, restore power, and run a test cycle to confirm normal heating and shutoff behavior. Tools needed: Phillips or nut driver (model-dependent), multimeter, vent brush or vacuum attachment for cleaning ductwork, work gloves.
Frequently Asked Questions
Some listings call this a "thermostat." Is it really a fuse?
Yes, genuinely a fuse. This is a common point of confusion across the marketplace — many third-party sellers label DC96-00887C a "thermostat," but it functions as a one-time thermal cut-off fuse. Once it opens from excess heat, it stays open permanently and cannot reset itself, unlike a true thermostat, which closes again automatically once temperatures drop. If your fuse has blown, replacement is the only option regardless of what a given listing calls it.
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. If airflow checks out and the fuse still blows, have the high-limit thermostat and thermistor checked as well, since a struggling thermostat can push this fuse to blow as the last line of defense.
How is this different from your DC47-00016A listing?
Both are one-time thermal fuses in the same dryer, but they mount in different locations and protect different points in the heating circuit. This DC96-00887C fuse is mounted on the blower housing; the DC47-00016A fuse is mounted on the heater can. They are not interchangeable, so check your parts diagram or the physical mounting location on your dryer to confirm which one you need.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Samsung OEM part, but is manufactured to match the electrical specifications, bracket configuration, and mounting position of the original DC96-00887C thermal fuse used in compatible Samsung and Kenmore electric dryers.
Shop With Confidence
A U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock components for all major appliance brands and offer fast shipping from our U.S. warehouse. Our team is available to help verify compatibility before you purchase.
✓ Quality Aftermarket Parts ✓ Fast US Shipping ✓ Compatibility Support ✓ Secure Checkout
XPARTCO 3392519 Dryer Thermal Fuse Replaces WP3392519
The XPARTCO 3392519 is an aftermarket replacement dryer thermal fuse compatible with select gas and electric dryers from Whirlpool, Kenmore, KitchenAid, Maytag, Roper, Estate, Inglis, Crosley, Amana, Admiral, and Magic Chef. The thermal fuse is a critical one-time-use safety device mounted on the exhaust duct or blower wheel housing that monitors the dryer's operating temperature.
When the dryer overheats — typically due to a clogged exhaust vent or restricted airflow — the thermal fuse permanently opens the circuit and cuts power to the heating system to prevent a fire. Once blown, the thermal fuse cannot be reset and must be replaced. This part measures 2 inches long x 1/2 inch wide, features two 3/16-inch terminals, and opens at approximately 196°F (91°C). Important: always check and clear the exhaust vent when replacing this fuse, as restricted airflow is the most common cause of thermal fuse failure.
Quick Answer
The XPARTCO 3392519 Dryer Thermal Fuse fixes dryers that won't start, won't heat, or stop mid-cycle due to overheating. It is a one-time-use safety fuse that permanently opens at 196°F (91°C) to cut power and prevent fires. Compatible with select Whirlpool, Kenmore, KitchenAid, Maytag, Roper, Estate, Inglis, Crosley, Amana, Admiral, and Magic Chef dryers. Replaces WP3392519 and many other part numbers.
Common Problems This Part Fixes
Dryer won't start at all
Dryer runs but produces no heat
Dryer stops mid-cycle and won't restart
Timer advances but drum does not heat
Dryer shuts off too soon before clothes are dry
No continuity detected across fuse terminals during testing
Replaces Part Numbers
This thermal fuse directly replaces the following OEM and cross-reference part numbers:
3392519, WP3392519, 3388651, WE4X857, G4AP0500, 6L4101, 6L4101091C, ET401, 3388651, 694511, 80005, AWP47582, PD00002311, EAP11741460, AP6008325, PS11741460
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal fuse is compatible with select gas and electric dryers from the following brands:
Whirlpool dryers (including Duet and Cabrio series)
Kenmore / Sears dryers (including Elite series)
KitchenAid dryers
Maytag dryers (including Centennial and Neptune series)
Roper dryers
Estate dryers
Inglis dryers
Crosley dryers
Amana dryers
Admiral dryers
Magic Chef dryers
Always verify your appliance model number before ordering. Contact our support team if you're unsure.
Key Features
One-time-use safety device — permanently opens at 196°F (91°C) to cut power and prevent dryer fires
Mounts on the exhaust duct or blower wheel housing — easy access for DIY replacement
Aftermarket replacement built to OEM-equivalent quality standards
2-terminal design — direct drop-in replacement, no modification required
Broad compatibility across 11 major appliance brands
DIY-friendly repair — installs with basic hand tools in under 30 minutes
Budget-friendly safety fix — one of the most common and least expensive dryer repairs
Product Specifications
Part Number
3392519
Part Type
Dryer Thermal Fuse
Condition
Aftermarket Replacement
Application
Gas and Electric Dryers
Opening Temperature
196°F (91°C)
Length
2 inches
Width
1/2 inch
Terminal Size
3/16 inch (2 terminals)
Resettable
No — one-time use only, must be replaced when blown
Location on Dryer
Exhaust duct / blower wheel housing
Compatible Brands
Whirlpool, Kenmore, KitchenAid, Maytag, Roper, Estate, Inglis, Crosley, Amana, Admiral, Magic Chef
Installation Notes
⚠️ Safety First — Unplug Dryer and Shut Off Gas Before Starting Unplug the dryer from the power source (and shut off the gas supply for gas dryers) before beginning any repair. The thermal fuse is located on the exhaust duct or blower wheel housing — access it by removing the back or front panel depending on your dryer model. Disconnect the two wire terminals from the old fuse, remove the fuse from its bracket, install the new fuse in the same position, reconnect the terminals, and reassemble the panel. Tools needed: Phillips screwdriver, 1/4-inch nut driver, and a multimeter to confirm the new fuse has continuity. ⚠️ Important: Before completing the repair, always check and clear the exhaust vent of any lint buildup — a blocked vent is the most common cause of thermal fuse failure and will blow the new fuse if not corrected.
Frequently Asked Questions
Will the 3392519 fit my dryer?
This thermal fuse is compatible with select gas and electric dryers from Whirlpool, Kenmore, KitchenAid, Maytag, Roper, Estate, Inglis, Crosley, Amana, Admiral, and Magic Chef. Use the model search above to verify your model, or contact our support team before ordering.
What does a dryer thermal fuse do?
The thermal fuse is a one-time-use safety device that monitors the temperature inside the dryer. When the dryer overheats — typically due to a clogged exhaust vent — the fuse permanently opens the circuit, cutting power to the heating system to prevent a fire. Once blown, it cannot be reset and must be replaced.
How do I know if my thermal fuse is blown?
Test the fuse with a multimeter set to continuity mode. Touch the probes to each of the two terminals. A working fuse will show continuity (beep or near-zero ohms). A blown fuse will show no continuity (open circuit). If there is no continuity, the fuse is blown and must be replaced.
Why did my thermal fuse blow?
The most common cause is restricted airflow due to a clogged or kinked exhaust vent, a plugged lint trap, or a damaged blower wheel. Always check and clear the exhaust vent before or after replacing the fuse — failing to do so will cause the new fuse to blow again.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Whirlpool OEM part, but is designed to deliver reliable overheat protection at a more affordable price point.
Shop With Confidence
Parts-O-Matic is a U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock parts for major appliance brands and ship quickly from our U.S. warehouse. Our team is available to help you verify compatibility before you buy.
✓ Fast US Shipping ✓ Quality Aftermarket Parts ✓ Compatibility Support ✓ Secure Checkout
XPARTCO 3390719 Dryer Thermal Fuse – Replaces WP3390719 – Compatible with Whirlpool, Maytag & Kenmore Dryers
Product Description
Restore safe dryer operation and proper heating with the XPARTCO 3390719 Dryer Thermal Fuse. This dryer Thermal Fuse is a replacement part for specific Whirlpool, Kenmore dryer models. This disposable, one-time fuse ensures safe operation of your appliance by cutting off power if the temperature exceeds safe limits. A bad thermal fuse can cause your appliance to stop functioning or prevent it from turning on altogether. Symptoms of a bad thermal fuse include no heat or a dryer that won't start. It is located on the blower housing and cannot be reset.
XPARTCO is a trusted aftermarket brand offering appliance replacement parts built to OEM-equivalent specifications at a cost-effective price.
Replaces Part Numbers
WP3390719, 3390719, 15-198, 279650, 3389639, 3389640, 660877, 688841, 690198, 690798, 80004, ET402, G4AP0401, PD00002330, EAP11741444, AP6008309, PS11741444.
Compatibility
This replacement dryer thermal fuse fits select Whirlpool, Maytag, Kenmore, Amana, Estate, Roper, and Crosley dryers.
Commonly installed on the blower housing or exhaust duct, depending on model.
Always verify your dryer’s model number before ordering.Contact our support team if you’re unsure.
✅ Key Features
🔄 Aftermarket Replacement – Matches OEM safety and temperature ratings
🛡️ Overheat Protection – Shuts off power if unsafe temperatures are detected
🔥 Fixes No-Heat or No-Run Issues – Common solution for blown fuse symptoms
🧩 Direct-Fit Design – Installs easily without modification
💰 Cost-Effective Repair – Reliable alternative to OEM thermal fuses
📐 Product Specification
Part Number: 3390719
Component Type: Dryer Thermal Fuse
Function: One-time over-temperature safety cutoff
Application: Blower housing or exhaust system
Mounting: Screw-mounted
Quality Level: Aftermarket replacement (not OEM)
🛠️ Installation Notes
Tools Needed: Phillips screwdriver, nut driver
⚠️ Safety First: Unplug the dryer before servicing to avoid electrical shock.
Basic Steps:
Disconnect dryer power.
Remove the rear or front access panel (model dependent).
Locate the thermal fuse on the blower housing or exhaust duct.
Disconnect wires and remove the old fuse.
Install the new XPARTCO 3390719 thermal fuse.
Reconnect wiring, reassemble panels, and restore power.
Test dryer operation.
⏱️ Time Required: 15–20 minutes
📦 Shop With Confidence
🚚 Free Shipping on All Orders
⚙️ Trusted Aftermarket Appliance Parts
🔄 30-Day Return Policy
Restore dryer safety and reliable operation — Add to Cart Now for a dependable, budget-friendly repair!
ERP W10909685 Dryer Thermal Fuse
Dryer thermal fuse located on the blower housing. If the dryer overheats, the thermal fuse blows cutting off power to the motor or the heating system. When the fuse is bad the dryer won't start or will run but not heat. The thermal fuse cannot be reset. Fuses often blow due to a clogged dryer vent.
Replaces part Numbers: W10909685, W10693363, G4AP0506, F 091C ACA2, PD00036363, EAP11766766, AP6034383, PS11766766.
This is an aftermarket part that can be used as a replacement for the OEM part. California Residents only
WARNING: Cancer and/or Reproductive Harm - www.p65warnings.ca.gov
XPARTCO 8573713 Gas Dryer Thermal Cut-Off Fuse Replaces WP8573713
The XPARTCO 8573713 is an aftermarket replacement thermal cut-off fuse for Whirlpool, Maytag, Kenmore, Crosley, Amana, and Inglis gas dryers. This fuse is mounted on top of the burner funnel, directly under the drum, and it's a one-time safety device: as long as the dryer stays within its normal operating temperature, it does nothing at all, but the instant temperatures near the burner climb high enough — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power. That's why a blown fuse produces such a specific symptom: the dryer won't heat, even though the drum may still tumble and the rest of the dryer seems to run normally.
Because this fuse sits on the burner funnel underneath the drum rather than on the more accessible blower housing, replacing it is a more involved repair than a typical thermal fuse swap — the drum has to come out of the cabinet to reach it. Unlike a resettable thermostat, this fuse cannot be reset once it blows; it must be replaced. A blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat near the burner is exactly what this fuse is designed to react to. It directly replaces WP8573713, AP6013467, and PS11746693.
Quick Answer
The XPARTCO 8573713 Gas Dryer Thermal Cut-Off Fuse fixes Whirlpool, Maytag, Kenmore, Crosley, Amana, and Inglis gas dryers that won't heat, even if the drum still tumbles normally. Mounted on the burner funnel under the drum. Replaces WP8573713, AP6013467, PS11746693. Always inspect and clean the dryer venting when replacing this fuse — a blown fuse is a symptom of restricted airflow, and installing a new fuse without fixing the vent will likely blow it again.
Common Problems This Part Fixes
Dryer runs and tumbles but produces no heat
Dryer that stopped heating suddenly, especially after running unusually hot
Drying times that have gotten noticeably longer or clothes coming out damp
Repeated blown fuses on a dryer with a known venting or airflow restriction
Dryer that recently smelled like burning or overheating before losing heat
Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This gas dryer thermal cut-off fuse directly replaces the following OEM and cross-reference part numbers:
WP8573713, 1180872, 8573713, AP3866211, EAP990558, PS990558, AWP49233, PD00006618
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal cut-off fuse is compatible with select Whirlpool gas dryers, and also fits select Maytag, Kenmore, Kenmore Elite, Crosley, Amana, Inglis, and Sears Canada gas dryers built on the Whirlpool platform, including model numbers such as WGD8500SR0, and Kenmore 11070372710 and 11071112020.
Note: This fuse is specific to gas dryers, mounted on the burner funnel. It is not the same fuse used on electric dryer platforms. Always verify your full model number before ordering. Contact our support team with your model number if you're unsure.
Key Features
Aftermarket replacement thermal cut-off fuse — one-time safety device that cuts power if the dryer overheats
Mounted on top of the burner funnel, directly under the drum
Resolves "runs but won't heat," "drying takes too long," and "clothes coming out damp" symptoms caused by a blown fuse
Replaces WP8573713, AP6013467, and PS11746693
Compatible with Whirlpool, Maytag, Kenmore, Kenmore Elite, Crosley, Amana, Inglis, and Sears Canada gas dryers
Aftermarket replacement built to OEM-equivalent quality standards
Product Specifications
Part Number
8573713
OEM Part Number
WP8573713
Part Type
Gas Dryer Thermal Cut-Off Fuse
Condition
Aftermarket Replacement
Application
Gas Dryers
Location
Top of the burner funnel, under the drum
Resettable
No — one-time use, must be replaced once blown
Material
Plastic housing
Dimensions
Approx. 1"H x 1"W
Repair Difficulty
Moderate to Hard — drum removal required for access
Quantity
1 thermal cut-off fuse
Compatible Brands
Whirlpool, Maytag, Kenmore, Kenmore Elite, Crosley, Amana, Inglis, Sears Canada
Installation Notes
⚠️ Gas Safety — Shut Off The Gas Supply Before Starting This fuse sits directly on the burner funnel, close to the gas burner assembly. Before beginning, close the gas shutoff valve behind the dryer in addition to unplugging the dryer or shutting off its circuit breaker. If at any point you smell gas, stop immediately, leave the area, and do not operate any switches — contact your gas utility or a qualified technician. Do not attempt this repair if you are not comfortable working safely around a gas appliance's burner assembly; a qualified technician can complete it instead.
⚠️ Drum Removal Required — Inspect And Clean The Venting Before Reassembling Wear work gloves. This repair requires removing the drum from the dryer cabinet to access the burner funnel, so budget more time and disassembly than a typical thermal fuse swap. Remove the top and front panels according to your model's service diagram, disconnect the drive belt from the idler pulley, and lift the drum out of the cabinet to expose the burner funnel underneath. Photograph the wiring before disconnecting the old fuse's connectors. Test the old fuse for continuity with a multimeter to confirm it's actually blown (no continuity) rather than assuming, and test the new fuse to confirm it's good out of the box. This is the most important step: fully inspect and clean the dryer's exhaust vent, from the lint trap housing all the way to the exterior vent hood, checking for lint buildup, crushed sections, or excessive length. A blown thermal fuse is a symptom of restricted airflow, and skipping this step means the new fuse is likely to blow again. Install the new 8573713 fuse on the burner funnel in the same mounting position, reconnect the wiring, and reassemble the drum, belt, and panels in reverse order. Restore the gas supply and power, and run a test cycle to confirm normal heating and shutoff behavior. Tools needed: Phillips or nut driver (model-dependent), multimeter, vent brush or vacuum attachment for cleaning ductwork, work gloves.
Frequently Asked Questions
My dryer tumbles fine but there's no heat. Is this the right part?
Yes, this is the classic symptom of a blown gas dryer thermal cut-off fuse. Because this fuse only interrupts the heating circuit and not the drive motor, the drum can continue tumbling completely normally while the dryer produces no heat at all. If you've confirmed the burner isn't igniting and the fuse tests as an open circuit, this is very likely the fix.
Why does this repair require removing the drum? My other dryer's fuse didn't need that.
This particular fuse is mounted on the burner funnel underneath the drum rather than on the blower housing at the back of the cabinet, which is where many thermal fuses on other platforms are located. Reaching the burner funnel requires taking the drum out of the cabinet, which is why this repair involves more disassembly than some other thermal fuse replacements.
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Whirlpool OEM part, but is manufactured to match the electrical specifications and mounting configuration of the original WP8573713 thermal cut-off fuse used in compatible Whirlpool, Maytag, Kenmore, Crosley, Amana, and Inglis gas dryers.
Shop With Confidence
A U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock components for all major appliance brands and offer fast shipping from our U.S. warehouse. Our team is available to help verify compatibility before you purchase.
✓ Quality Aftermarket Parts ✓ Fast US Shipping ✓ Compatibility Support ✓ Secure Checkout
XPARTCO 137032600 Dryer Thermal Fuse – Compatible with Frigidaire, Electrolux, and Kenmore Dryers
Product Description
Protect your dryer from overheating with the XPARTCO 137032600 Dryer Thermal Fuse. This high-quality aftermarket replacement acts as a safety device that shuts off power to the heating element if the dryer overheats. A blown fuse can cause the dryer to stop heating or fail to start. Replacing it with this reliable and affordable XPARTCO fuse ensures safe operation and restores your dryer’s performance.
Replaces Part Numbers
137032600, 137060800, 1483164, 7137032600, AH2349395, EA2349395, PD00000890, EAP2349395, AP4368739, PS2349395.
Compatibility
This replacement thermal fuse fits select Frigidaire, Electrolux, and Kenmore dryers.
Example compatible models include (but are not limited to): Frigidaire AEQ6000ES0, Electrolux EIED55HIW0, and Kenmore 417.88042700.
Always verify your dryer’s model number before ordering. Contact our support team if you’re unsure.
✅ Key Features
🔄 Aftermarket Replacement – Designed to match OEM performance for Frigidaire and Electrolux dryers
🔥 Safety Protection – Prevents overheating by cutting off power to the heating element
💰 Cost-Effective Fix – Affordable alternative to expensive OEM replacements
🛠️ Easy Installation – Direct-fit design for simple DIY replacement
🛡️ Fixes Common Issues – Restores heat function and resolves dryer not starting or heating problems
📐 Product Specification
Part Number: 137032600
Component Type: Dryer Thermal Fuse
Material: Heat-resistant plastic and metal housing
Mounting: Direct-fit installation on heater housing
Operating Conditions: Designed for residential electric dryers
Compliance: Built to OEM-equivalent quality standards (not OEM)
🛠️ Installation Notes
Tools Needed: Phillips screwdriver, nut driver
⚠️ Safety First: Always unplug the dryer before performing any repairs to prevent electrical shock.
Steps:
Disconnect power and move dryer away from the wall.
Remove the rear access panel to locate the thermal fuse.
Disconnect wires and remove screws securing the old fuse.
Install the new XPARTCO 137032600 fuse and reconnect wires.
Reattach the back panel, restore power, and test heating function.
⏱️ Time Required: 10–15 minutes
📦 Shop With Confidence
🚚 Free Shipping on All Orders
🧰 Trusted Appliance Parts Supplier
🔄 30-Day Return Policy
Protect your dryer and restore performance — Add to Cart Now for a reliable, budget-friendly replacement!
134120900 Genuine OEM Dryer Thermal Fuse - Compatible with Frigidaire, Electrolux, Kenmore
Product Description
Ensure your dryer operates safely with the 134120900 Genuine OEM Dryer Thermal Fuse. This Frigidaire-manufactured thermal limiter, with a 220°F limit, is designed to prevent overheating in select Frigidaire, Electrolux, Kenmore, and other compatible dryers by cutting off power if the dryer exceeds safe temperatures. It addresses issues like the dryer not starting, shutting off too soon, or overheating, ensuring safe and reliable performance. This non-resettable fuse must be replaced if blown.
Note: Includes (1) thermal fuse. Disconnect power before installation. Verify compatibility with your dryer model.
Replaces part numbers: 134120900, 146062-0, 146062-00, 146062-000, 1489053, 3205659, 5303209192, AH419402, EA419402, PD00000113, EAP419402, AP2108182, PS419402.
Compatibility:
Compatible with select dryer and washer/dryer combo models, including but not limited to:
Frigidaire: LEQ1442ES0, FDE436RES0, FDE546RES0, FDE558GES0
Electrolux: EKDR14XAKW0, FFLE1011MW2, FFLE2022MW2, FFLE3911QW0
Kenmore: 417.49012890, 417.49022890, 417.97561601
Crosley: BEQ1442CES0, CDE2000FW0, CDE4000FW0
White-Westinghouse: WDE336RES0
Common models: Frigidaire FDE216RES0, Electrolux FFLE4033QW0, Kenmore 417.97591220
Verify your model number or contact our support team for assistance.
Key Features:
✅ Brand and Models Compatibility: Fits select Frigidaire, Electrolux, Kenmore, Crosley, White-Westinghouse, and other dryers.
🔧 Specifications: Genuine OEM Frigidaire thermal fuse, 220°F limit, non-resettable.
💪 Reliable Performance: Prevents overheating by cutting power, ensuring safe dryer operation.
🛠️ Easy Installation: Requires a screwdriver and pliers; typically installed in 15–20 minutes.
🛡️ Effective Fixes: Resolves dryer not starting, shutting off too soon, overheating, or no heat issues.
Product Specification
Part Number: 134120900
Component Type: Dryer thermal fuse (thermal limiter)
Material: Metal and plastic
Operating Conditions: 220°F limit, 125/250V
Compliance: UL-listed, Prop 65 warning for California
Installation Notes:
Safety First: Disconnect the dryer from the power source before installation.
Shop for high-quality appliance parts with a 30-day return policy. Keep your dryer running safely today!
Add to cart now for a reliable fix!
XPARTCO 3387134 - 3392519 Dryer Cycling Thermostat and Thermal Fuse Set - Compatible with Whirlpool, Kenmore, Maytag
Product Description
Maintain safe and efficient dryer operation with the XPARTCO 3387134 - 3392519 Dryer Cycling Thermostat and Thermal Fuse Set. This replacement kit includes one cycling thermostat (3387134, L155-25) and one thermal fuse (3392519), designed as a replacement for select Whirlpool, Kenmore, Maytag, and other compatible dryers. The cycling thermostat regulates drum temperature, while the thermal fuse prevents overheating by cutting power if temperatures exceed safe limits. This set addresses issues like overheating, insufficient heat, no heat, or prolonged drying times. Test the thermal fuse first if the dryer won't heat, as it typically fails before the thermostat.
Note: Includes (1) cycling thermostat and (1) thermal fuse. Disconnect power before installation. Verify compatibility with your dryer model.
Replaces part numbers:
Cycling Thermostat: WP3387134, 3387134, 3387135, 3387139, 3-6910, 306910, 326801, 661512, L150-15F, L155-25F, AP6008270, PS11741405.
Thermal Fuse: 3392519, WP3392519, 3388651, WE4X857, G4AP0500, 6L4101091C, ET401, 3388651, 694511, 80005, PS11741460, AP6008325.
Compatibility:
Compatible with select dryer models, including but not limited to:
Whirlpool: LE5700XKW0, LE5920XKW0, WED4815EW1, WED4910XQ1, WED5300SQ0
Kenmore: 110.97591420, 110.97591220, 110.97592420, 110.60072990
Maytag: MDE5500AYW, MDE6000AYW, MDE7600AYW
Roper: RED4440VQ1, REX5634KQ1
Amana: NED4655EW0
KitchenAid: KEYE760WWH0
Verify your model number or contact our support team for assistance.
Key Features:
✅ Brand and Models Compatibility: Fits select Whirlpool, Kenmore, Maytag, Roper, Amana, KitchenAid, and other dryers.
🔧 Specifications: Replacement kit with one cycling thermostat (L155-25 SPST, 120V, 2W) and one thermal fuse (250°F limit, non-resettable).
💪 Reliable Performance: Regulates drum temperature and prevents overheating for safe, efficient drying.
🛠️ Easy Installation: Requires a screwdriver and pliers; typically installed in 15–30 minutes.
🛡️ Effective Fixes: Resolves overheating, insufficient heat, no heat, or prolonged drying times.
Product Specification
Part Number: XPARTCO 3387134 - 3392519
Component Type: Dryer cycling thermostat and thermal fuse kit
Material: Plastic and metal
Electrical Specs:
Cycling Thermostat: 120V, 2W; L155-25 SPST, opens at 155°F, closes at 130°F
Thermal Fuse: 250°F limit, 125/250V, non-resettable
Compliance: Prop 65 warning for California
Installation Notes:
Safety First: Disconnect the dryer from the power source before installation.
Shop for high-quality appliance parts with a 30-day return policy. Keep your dryer running safely and efficiently today!
Add to cart now for a reliable fix!
XPARTCO 8318314 Dryer Thermal Cutoff Fuse (352°F)
The XPARTCO 8318314 is an aftermarket replacement 352°F thermal cutoff fuse compatible with a wide range of Whirlpool, Maytag, KitchenAid, Kenmore, Amana, Crosley, Roper, Inglis, and Estate dryers. The thermal cutoff fuse is a critical safety device mounted near the heating element housing — it acts as a backup safety in case the high-limit thermostat fails to open. When the air temperature inside the heating element area reaches 352°F, the fuse permanently opens and cuts power to the heater circuit, preventing the dryer from continuing to overheat and creating a fire risk.
This is a one-time fuse — once it has tripped, it cannot be reset and must be replaced. White and gray metal/ceramic construction. Dimensions: 1-1/4"L x 1-1/4"W x 2-3/16"H, with approximately 1-5/8" between mounting holes (center to center). It directly replaces 8318314. Important: when the thermal cutoff blows, the high-limit thermostat (8557403 — sold separately) is often also stressed and should be tested or replaced at the same time. Installs in 15–20 minutes with basic hand tools.
Quick Answer
The XPARTCO 8318314 Dryer Thermal Cutoff Fuse (352°F) fixes Whirlpool, Maytag, KitchenAid, Kenmore, Amana, Crosley, Roper, Inglis, and Estate dryers that suddenly stopped heating after an overheat event. One-time fuse — 352°F open, must be replaced once blown. 1-1/4"L x 1-1/4"W x 2-3/16"H, ~1-5/8" between mounting holes. Metal/ceramic. Often replaced alongside the high-limit thermostat (8557403, sold separately).
Common Problems This Part Fixes
Dryer suddenly stopped heating with no warning — thermal cutoff has blown after an overheat event
Dryer runs and tumbles normally but produces no heat
No-heat fault following a partially blocked exhaust vent or restricted airflow event
Multimeter continuity test shows the cutoff has an open circuit (no continuity)
Visible damage or discoloration around the thermal cutoff housing from a prior overheat event
Repeated no-heat problems where the thermal cutoff has tripped more than once
Replaces Part Numbers
This thermal cutoff fuse directly replaces the following OEM and cross-reference part numbers:
8318314
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This 352°F thermal cutoff fuse is compatible with select dryers from the following brands:
Whirlpool dryers (Elite, Cabrio, Duet, and WED series — select models including WED9200, WED7300, WED7400, WED7600 and related)
Maytag dryers (Maxima and MED series — select models including MED3500, MED6000XW, MEDE900VW and related)
KitchenAid dryers (select models)
Kenmore / Sears dryers — Elite 110-series and related Whirlpool-built models
Amana dryers — NED and YNED series (select models including NED7500VW1 and related)
Crosley dryers (CED series and related models)
Roper dryers (select models)
Inglis dryers (select models)
Estate dryers (select models)
Important — Check Vent Before Restarting: A blown thermal cutoff is almost always the result of restricted dryer airflow. Before replacing this fuse and restoring service, thoroughly clean the dryer's exhaust vent line all the way to the exterior wall outlet, the lint screen, and any internal lint buildup. Installing a new thermal cutoff without fixing the underlying airflow problem will cause the new fuse to blow within a short time, repeating the failure.
Key Features
352°F one-time safety fuse — permanently opens to cut power to the heater circuit if the dryer overheats
Backup safety device — protects against overheating in case the high-limit thermostat fails to open
Cannot be reset — must be replaced once blown
Dimensions: 1-1/4"L x 1-1/4"W x 2-3/16"H; approximately 1-5/8" between mounting holes (center to center)
Metal and ceramic construction in white/gray
Often replaced together with the high-limit thermostat (8557403, sold separately) as a paired safety repair
Compatible with Whirlpool, Maytag, KitchenAid, Kenmore, Amana, Crosley, Roper, Inglis, and Estate dryers
Aftermarket replacement built to OEM-equivalent quality standards
Quick DIY repair — installs in 15–20 minutes with basic hand tools
Product Specifications
Part Number
8318314
Part Type
Dryer Thermal Cutoff Fuse (Safety Fuse)
Condition
Aftermarket Replacement
Application
Electric and Gas Dryers (Whirlpool platform)
Trip Temperature
352°F
Fuse Type
One-Time (must be replaced once blown — cannot be reset)
Dimensions
1-1/4"L x 1-1/4"W x 2-3/16"H
Mounting Hole Spacing
Approx. 1-5/8" center to center
Color
White / Gray
Material
Metal / Ceramic
Often Replaced With
High-Limit Thermostat (8557403, sold separately)
Compatible Brands
Whirlpool, Maytag, KitchenAid, Kenmore, Amana, Crosley, Roper, Inglis, Estate
Installation Notes
⚠️ Unplug Dryer Before Starting — Clean Vent System First Disconnect power before beginning. Wear work gloves to protect your hands. Before installing the new thermal cutoff, thoroughly clean the dryer's vent line — from the lint screen through the duct to the exterior wall outlet, plus any internal lint buildup around the heater housing. A blown thermal cutoff is virtually always caused by restricted airflow; if you don't fix the underlying cause, the new fuse will trip again soon. Access the thermal cutoff by removing the rear (or front, depending on model) access panel of the dryer to expose the heating element housing. The 8318314 thermal cutoff is mounted on or near the heater housing. Photograph the wire connections before disconnecting. Disconnect the wires from the old cutoff and remove the mounting screw(s). Install the new 8318314 cutoff in the same position and reconnect the wires. While the panel is open, this is also the ideal time to test or replace the high-limit thermostat (8557403) — overheat events that blow this fuse often damage that component too. Reassemble the panel, restore power, and run a test heat cycle to confirm normal heat operation. Tools needed: Phillips screwdriver, 1/4" nut driver, multimeter, work gloves.
Frequently Asked Questions
What's the difference between a thermal cutoff, a thermal fuse, and a high-limit thermostat?
All three are safety components in a dryer's heating circuit but they serve different roles. The high-limit thermostat (such as 8557403 or 3391914) is a resettable safety switch — it opens when the air gets too hot, then closes again automatically once it cools. The thermal cutoff (8318314, 352°F) is a one-time fuse on the heating element circuit — it blows permanently if the temperature exceeds 352°F, meaning the high-limit thermostat failed to do its job. The thermal fuse (often 3392519) is a separate one-time fuse mounted on the exhaust duct — it blows if exhaust airflow temperature exceeds its rating. Each protects against a different failure mode and is replaced individually when it blows.
Why did my thermal cutoff blow in the first place?
A blown thermal cutoff is almost always the result of restricted airflow through the dryer. The most common causes are: a clogged or kinked exhaust vent line, a clogged lint screen, lint buildup inside the dryer cabinet near the heater housing, or a failed blower wheel/motor that's not moving enough air. Less commonly, a failed high-limit thermostat (stuck closed) can let the dryer overheat until the thermal cutoff blows as a last-resort safety. Before replacing this part, identify and fix the underlying airflow issue — otherwise the new fuse will blow within a short time.
Should I replace the high-limit thermostat at the same time?
Yes, it's highly recommended. The thermal cutoff is the second line of defense against overheating — for it to trip, the high-limit thermostat ahead of it likely failed to open at its normal cycling temperature, was stressed by the overheat event, or was already weakened. Replacing the high-limit thermostat (8557403 on many compatible Whirlpool-platform dryers) at the same time is standard practice and ensures both safety components work correctly together. The 279973 kit even bundles a thermal cutoff with a high-limit thermostat for this reason.
Can the thermal cutoff be reset like a circuit breaker?
No — the 8318314 is a one-time thermal fuse. Once it opens at 352°F, it permanently breaks the electrical circuit and cannot be reset. Some appliance components (like a high-limit thermostat) can reset automatically as they cool, but a thermal cutoff fuse is a single-use safety device by design. If your dryer suddenly stopped heating and a continuity test on this fuse shows an open circuit, it must be replaced.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Whirlpool OEM part, but is manufactured from metal and ceramic with the same 352°F trip temperature, dimensions (1-1/4"L x 1-1/4"W x 2-3/16"H), and mounting hole spacing (1-5/8" center to center) as the original 8318314 thermal cutoff fuse.
Shop With Confidence
A U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock components for all major appliance brands and offer fast shipping from our U.S. warehouse. Our team is available to help verify compatibility before you purchase.
✓ Fast US Shipping ✓ Quality Aftermarket Parts ✓ Compatibility Support ✓ Secure Checkout
XPARTCO 6931EL3003D Dryer Hi-Limit Thermal Fuse
Replaces Part Numbers: 6931EL3003D, 1268366, 6931EL3003E, AH3530485, EA3530485, AP4440975, PS3530485
Description: This Hi Limit Thermal Fuse is a replacement part for Kenmore, LG dryer models. This fuse is a safety device that protects the dryer from overheating by cutting off power to the heating element if the dryer’s temperature exceeds a safe limit. It ensures that the dryer operates within safe temperature ranges, preventing potential fire hazards.
This is an aftermarket part that can be used as a replacement for the OEM part.
XPARTCO DC47-00016A Dryer Thermal Fuse
The XPARTCO DC47-00016A is an aftermarket replacement thermal fuse for Samsung dryers. Mounted on the blower housing near the heat source, this fuse is a one-time safety device: as long as the dryer stays within its normal operating temperature, it does nothing at all, but the instant internal temperatures climb dangerously high — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power to the dryer. That's why a blown thermal fuse produces such a specific symptom: the dryer won't start at all, with no lights, no tumble, and no response, even though the outlet has power.
This fuse terminates in 1/4" male spade connectors for a direct plug-in fit. Unlike a thermostat, a thermal fuse cannot be reset once it blows — it must be replaced. Critically, a blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat is exactly what the fuse is designed to react to. A failing thermistor can also cause repeated fuse blows, since the two work together to regulate temperature. It directly replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, and 35001087.
Quick Answer
The XPARTCO DC47-00016A Dryer Thermal Fuse fixes Samsung dryers that won't start at all — no lights, no tumble, no response to any button — after overheating from restricted airflow. 1/4" male spade terminals. Replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, 35001087. Always inspect and clean the dryer venting when replacing this fuse — a blown fuse is a symptom of restricted airflow, and installing a new fuse without fixing the vent will likely blow it again.
Common Problems This Part Fixes
Dryer won't start at all — no lights, no tumble, no response to any button
Dryer that stopped working suddenly, especially after a load felt unusually hot
Dryer runs a short time then shuts off completely and won't restart
Repeated blown fuses on a dryer with a known venting or airflow restriction
Clothes coming out extremely hot right before the dryer stopped working
Dryer that recently smelled like burning or overheating before failing
Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermal fuse directly replaces the following OEM and cross-reference part numbers:
DC47-00016A, L0016A, AP4201894, PS4205213, AP6008681, EAP4205213, OEM12605691, EAP11741821, ASM868996, PD00005341, PD00003747, PS11741821, 35001087, WP35001087.
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal fuse is compatible with select Samsung dryers, and also fits select LG and Kenmore dryers built on a compatible platform, including model numbers such as:
DV209AEW/XAA, DV210AEW, DV210AEW/XAA
DV218AEB/XAA, DV218AEW/XAA, DV219AEW/XAA, DV220AEW, DV220AEW/XAA
DV330AEW, DV350AEW/XAA, DV419AEW/XAA
Note: This fuse is commonly paired with a matching thermistor (DC32-00007A) and thermostat (DC96-00887A / DC47-00018A), and manufacturer guidance recommends replacing the thermistor at the same time as the fuse, since the two work together and a failing thermistor is a common cause of repeated fuse blows. Always verify your full model number before ordering. Contact our support team with your model number if you're unsure.
Key Features
Aftermarket replacement thermal fuse — one-time safety device that cuts power if the dryer overheats
Resolves "won't start at all," "stopped working suddenly," and "clothes came out extremely hot before it died" symptoms caused by a blown fuse
1/4" male spade terminal connectors for a direct plug-in electrical fit
Mounts to the blower housing near the heat source
Replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, and 35001087
Compatible with select Samsung, LG, and Kenmore dryers
Aftermarket replacement built to OEM-equivalent quality standards
Quick, simple repair — no special tools required beyond a basic screwdriver
Product Specifications
Part Number
DC47-00016A
OEM Part Number
DC47-00016A
Part Type
Dryer Thermal Fuse (Thermal Cut-Off)
Condition
Aftermarket Replacement
Location
Blower housing, near the heat source
Terminals
1/4" male spade connectors
Resettable
No — one-time use, must be replaced once blown
Companion Parts
Thermistor DC32-00007A, thermostat DC96-00887A / DC47-00018A
Quantity
1 thermal fuse
Compatible Brands
Samsung, LG, Kenmore
Installation Notes
⚠️ Unplug Dryer Before Starting — Inspect And Clean The Venting Before Reassembling Disconnect power at the outlet or shut off the circuit breaker before beginning. Wear work gloves. Access is typically through the rear panel: remove the screws securing the panel to reach the blower housing where the fuse is mounted, usually alongside the thermistor. Photograph the wiring before disconnecting the spade terminals from the old fuse. Remove the mounting screw holding the fuse in place and pull it free, disconnecting both spade terminal wires. Before installing the new fuse, test it for continuity with a multimeter to confirm it's good out of the box, and test the old one to confirm it's actually blown (no continuity) rather than assuming. This is the most important step: fully inspect and clean the dryer's exhaust vent, from the lint trap housing all the way to the exterior vent hood, checking for lint buildup, crushed sections, or excessive length. A blown thermal fuse is a symptom of restricted airflow, and skipping this step means the new fuse is likely to blow again. Install the new DC47-00016A in the same mounting position, reconnect both spade terminals, and secure the mounting screw. Reinstall the rear panel, restore power, and run a test cycle to confirm normal heating and shutoff behavior. Tools needed: Phillips or nut driver (model-dependent), multimeter, vent brush or vacuum attachment for cleaning ductwork, work gloves.
Frequently Asked Questions
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. If airflow checks out and the fuse still blows, have the thermistor and thermostat checked as well, since a failing thermistor can also trigger repeated fuse blows.
Can I just reset the thermal fuse instead of replacing it?
No. Unlike a thermostat, a thermal fuse is a one-time safety device — once it blows, its internal circuit is permanently broken and it cannot be reset or repaired. Replacement is the only option.
Should I replace the thermistor at the same time as the fuse?
It's worth strongly considering, and it's a common manufacturer recommendation. The thermistor and thermal fuse work together to manage temperature, and a failing thermistor can cause the dryer to run hotter than it should, leading directly to repeated fuse blows. Replacing both together, especially if your dryer has blown this fuse more than once, addresses the more likely root cause rather than just the symptom.
My clothes came out extremely hot right before the dryer died. Is that related?
Yes, this is a classic warning sign. Clothes coming out unusually hot indicates the dryer was already running hotter than normal, which is exactly the condition that leads to a blown thermal fuse. If you noticed this before the dryer stopped working, it strongly points to a ventilation or airflow problem that should be fully addressed before running the dryer again.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Samsung OEM part, but is manufactured to match the electrical specifications, spade terminal connections, and mounting configuration of the original DC47-00016A thermal fuse used in compatible Samsung, LG, and Kenmore dryers.
Shop With Confidence
A U.S.-based appliance parts retailer specializing in genuine OEM and high-quality replacement parts. We stock components for all major appliance brands and offer fast shipping from our U.S. warehouse. Our team is available to help verify compatibility before you purchase.
✓ Quality Aftermarket Parts ✓ Fast US Shipping ✓ Compatibility Support ✓ Secure Checkout